8115405204 - LFx1.0-10 TM 50 230/1/50 CE
• Max Working Pressure - 10BAR
• Vessel size - 50
• Supply - 230/1/50
• Motor Power (kW) - 0.75
Product Description
LFx, a single stage Oil Free reciprocating compressor designed for operation at maximum
pressure of 10 bar (145psi) and capacities from 1.02 up to 2.53 l/s at 50Hz, 2.86 to 5.06 cfm at
60 Hz.
Working Principle:
Filtered air is entered through the inlet valve into both cylinders. The piston is driven forward
through the connection rod attached to the balanced crankshaft. The air is compressed in the
cylinder that leaves through the outlet valve when the required pressure of 10 bar (145 psi) is
reached.
Scope of Supply:
Drive arrangement
The standard drive arrangement is direct drive with electrical motor. However, the compressor
block can also be directly driven by a hydraulic motor, diesel or petrol motor and kit is available
for belt drive arrangement.
Electrical Regulation
The standard electrical regulation occurs by means of pressure switch that starts/stops the
compressor at pre-set pressures. Al units are also supplied with over load relay. In standard
models, the cylinder heads are always de-pressurized if the units is stopped via pressure switch.
On units with Direct on Line (DOL) start this is done through the pneumatic Unloader located
inside the pressure switch box. Units with Y/D start are supplied with an Industrial Unloader
Valve and Solenoid valve to de-pressurized the cylinder heads both stopping and starting the
unit. Starting the compressor without back pressure in combination with special Y/D motor
dramatically reduces start-up current. A cubicle is needed to manage the motor running between
Y and D and to control the Industrial Unloader Valve.
Pricing
List price | Discount | Net price | |
---|---|---|---|
- | - | - |
Product information
Specification | Value |
---|---|
Weight | 49000 GRM |
Technical details
Specification | Value |
---|---|
Air receiver mounted | Receiver mounted |
Component approval electrical | IEC |
Component approval mechanical | CE |
Frequency | 50 Hz |
Integrated dryer | No |
Number of phases | 1 phase |
Supply voltage | 230 V |
Working pressure | 10 bar |
Certification | CE |
Starter | DOL |
Installed motor power (kW) | 0.75 kW |